Search

The Online Encyclopedia and Dictionary

 
     
 

Encyclopedia

Dictionary

Quotes

   
 

Capacitance

Capacitance is the ability of a capacitor to store potential difference or voltage for a given amount of stored charge. The SI unit of capacitance is the farad.

C = \frac{Q}{V}

where

C is the capacitance, measured in farads

Q is the charge, measured in coulombs

V is the potential difference, measured in volts

A capacitor has a capacitance of one farad when one coulomb of charge causes a potential difference of one volt across the capacitor. Since the farad is a very large unit, values of capacitors are usually expressed in microfarads (μF), nanofarads (nF) or picofarads (pF).

The above equation is only accurate for values of Q which are much larger than the electron charge e = 1.602·10-19 C. For example, if a capacitance of 1 pF is charged to a voltage of 1 µV, the equation would predict a charge Q = 10-19 C, but this is impossible as it is smaller than the charge on a single electron. However, recent experiments and theories (e.g. the fractional quantum Hall (FQH) effect) have suggested the existence of fractional charges.

The capacitance of a parallel-plate capacitor constructed of two identical plane electrodes of area A at constant spacing d is approximately equal to the following:

C = \epsilon_0 \epsilon_r \frac{A}{d}

where

C is the capacitance in farads

ε0 is the electrostatic permittivity of vacuum or free space, measured in farad per metre

εr is the dielectric constant or relative permittivity of the insulator used

A is the area of each plane electrode, measured in square metres

d is the separation between the electrodes, measured in metres

1 SI electricity units
2 See also
3 External links

Contents

Energy

The energy (measured in joules) stored in a capacitor is equal to the work done to charge it up. Consider a capacitor with capacitance C, holding a charge +q on one plate and -q on the other. Moving a small element of charge dq from one plate to the other against the potential difference V = q/C requires the work dW:

dW = \frac{q}{C}dq

where

W is the work measured in joules

q is the charge measured in coulombs

C is the capacitance, measured in farads

We can find the energy stored in a capacitor by integrating this equation. Starting with an uncharged capacitor (q=0) and moving charge from one plate to the other until the plates have charge +Q and -Q requires the work W:

W_{charging} = \int_{0}^{Q} \frac{q}{C} dq = \frac{1}{2}\frac{Q^2}{C} = \frac{1}{2}CV^2 = W_{stored}

Combining this with the above equation for the capacitance of a flat-plate capacitor, we get:

W_{stored} = \frac{1}{2} \epsilon_0 \epsilon_r \frac{A}{d} V^2

If the maximum voltage a capacitor can withstand is V_{max} \, (equal to E_{str}d \, where E_{str} \, is the dielectric strength), then the maximum energy it can store is:

W_{max} = \frac{1}{2} \epsilon_0 \epsilon_r V_{str}^2 A d

In the design of a capacitor, the main variables are the choice of dielectric, and the "plate" dimensions. The selection of dielectric determines the relative permittivity and breakdown strength, and hence the energy capacity per unit volume of dielectric.

In electric circuits

Electrons cannot directly pass across the dielectric from one plate of the capacitor to the other. When a voltage is applied to a capacitor through an external circuit, current flows to one plate, charging it, while flowing away from the other plate, charging it oppositely. In other words, when the voltage across a capacitor changes, the capacitor will be charged or discharged. The associated current is given by

I = \frac{dQ}{dt} = C\frac{dV}{dt}

where

I is the current flowing in the conventional direction, measured in amperes

dV/dt is the time derivative of voltage, measured in volts / second.

In the case of a constant voltage (DC), an equilibrium is soon reached, where the charge of the plates corresponds with the applied voltage by the relation Q=CV, and no further current will flow in the circuit. Therefore direct current cannot pass. However, effectively alternating current (AC) can: every change of the voltage gives rise to a further charging or a discharging of the plates and therefore a current. The amount of "resistance" of a capacitor to AC is known as capacitive reactance, and varies depending on the AC frequency. Capacitive reactance is given by this formula:

X_C = \frac{1}{2 \pi f C}

where

XC = capacitive reactance, measured in ohms

f = frequency of AC in hertz

C = capacitance in farads

Thus the reactance is inversely proportional to the frequency. Since DC has a frequency of zero, the formula confirms that capacitors completely block direct current. For high-frequency alternating currents the reactance is small enough to be considered as zero in approximate analyses.

Reactance is so called because the capacitor doesn't dissipate power, but merely stores energy. In electrical circuits, as in mechanics, there are two types of load, resistive and reactive. Resistive loads (analogous to an object sliding on a rough surface) dissipate energy that enters them, ultimately by electromagnetic emission (see Black body radiation), while reactive loads (analogous to a spring or frictionless moving object) retain the energy.

The impedance of a capacitor is given by:

Z = \frac{-j}{2 \pi f C} = {1 \over j 2 \pi f C}

where

j is the imaginary unit = \sqrt{-1}

Hence, capacitive reactance is the negative imaginary component of impedance. The negative sign indicates that the current leads the voltage by 90° for a sinusoidal signal, as opposed to the inductor, where the current lags the voltage by 90°.

Also significant is that the impedance is inversely proportional to the capacitance, unlike resistors and inductors for which impedances are linearly proportional to resistance and inductance respectively. This is why the series and shunt impedance formulae (given below) are the inverse of the resistive case. In series, impedances sum. In shunt, conductances sum.

In a tuned circuit such as a radio receiver, the frequency selected is a function of the inductance (L) and the capacitance (C) in series, and is given by

f = \frac{1}{2 \pi \sqrt{LC}}

This is the frequency at which resonance occurs in an RLC series circuit.

Capacitor networks

Capacitors in a parallel configuration each have the same potential difference (voltage). To find their total equivalent capacitance (Ceq):

A diagram of several capacitors, side by side, both leads of each connected to the same wires
C_{eq} = C_1 + C_2 + \cdots + C_n \,

The current through capacitors in series stays the same, but the voltage across each capacitor can be different. The sum of the potential differences (voltage) is equal to the total voltage. To find their total capacitance:

A diagram of several capacitors, connected end to end, with the same amount of current going through each
\frac{1}{C_{eq}} = \frac{1}{C_1} + \frac{1}{C_2} + \cdots + \frac{1}{C_n}

One possible reason to connect capacitors in series is to increase the overall voltage rating. In practice, a very large resistor might be connected across each capacitor to divide the total voltage appropriately for the individual ratings.

Capacitor/inductor duality

In mathematical terms, the ideal capacitor can be considered as an inverse of the ideal inductor, because the voltage-current equations of the two devices can be transformed into one another by exchanging the voltage and current terms.

Just as two or more inductors can be magnetically coupled to make a transformer, two or more charged conductors can be electrostatically coupled to make a capacitor. The mutual capacitance of two conductors is defined as the current that flows in one when the voltage across the other changes by unit voltage in unit time.

SI electricity units

SI electromagnetism units

Name Symbol Dimensions Quantity
ampere (SI base unit) A C / s Current
coulomb C A · s Electric charge, Quantity of electricity
volt V J / C = kg m2 / (s2 C) Potential difference
ohm Ω V / A = kg m2 / (C2) Resistance, Impedance, Reactance
ohm &middot metre Ω &middot m kg m3 / (C2) Resistivity
farad F C / V = C2 s / (kg m2) Capacitance
farad per metre F / m C2 s / (kg m3) Permittivity
reciprocal farad F−1 kg m2 / (C2 s) Elastance
siemens S Ω−1 = C2 / (kg m2) Conductance, Admittance, Susceptance
siemens per metre S / m C2 / (kg m3) Conductivity
weber Wb V &middot s = kg m2 / (C s) Magnetic flux
tesla T Wb / m2 = kg / (C s) Magnetic flux density
ampere / metre A / m C / (s m) magnetic induction
ampere-turns / weber A / Wb C2 / (kg m2) Reluctance
henry H V &middot s / A = kg m2 s / (C2) Inductance
henry per metre H / m kg m s / (C2) Permeability
(dimensionless) - - Magnetic susceptibility


See also

External links




Last updated: 02-05-2005 00:18:34